Radial-to-femoral pressure gradient quantification in cardiac surgery

2021 
Abstract Background A radial-to-femoral pressure gradient (RFPG) can occur in roughly one-third of cardiac surgical patients. Such a gradient has been associated with smaller stature and potentially smaller radial artery diameter. We hypothesized that preoperative radial artery diameter could be a predictor of RFPG. We also investigated the clinical impact of using a femoral versus a radial arterial catheter in terms of vasoactive support. Methods Using ultrasound, we measured the bilateral radial artery diameters of 160 cardiac surgical patients. All arterial pressure values were continuously recorded. Significant RFPG was defined as ≥25 mm Hg in systolic and/or ≥10 mm Hg in mean arterial pressure. One hundred and forty-nine additional patients were used to validate the impact of our observations. Results Using 78,013 pressure datapoints in 129 patients, 34.8% of patients had an RFPG with a mean duration of 54 ± 48 minutes. Patients with a radial artery diameter Conclusions A significant RFPG occurs in one-third of cardiac surgical patients and in 48% of those with a radial artery diameter
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    40
    References
    1
    Citations
    NaN
    KQI
    []