Performance of 112 MHz SRF Gun at BNL

2020 
A 112 MHz SRF electron photoinjector (gun) was developed at Brookhaven National Laboratory to produce high-brightness and high-bunch-charge bunches for the coherent electron cooling proof-of-principle experiment. The gun is designed to deliver electrons with a kinetic energy of up to 2 MeV. Electrons are generated by illuminating a high quantum efficiency (QE) K2CsSb photoemission layer with a green laser operating at a wavelength of 532 nm. The gun was able to generating 3 nC bunches at 1.7 MeV. The design goals, fabrication, performance and operational experience are reported here.