Stress Rate and Proof‐Testing of Silicon Wafers

1985 
Fracture mechanics test methods were applied to evaluate the proof-test characteristics of single-crystal silicon wafers. The results indicate that the strength distribution of silicon wafers is truncated by proof-testing. No subcritical crack growth occurred during proof-loading, as inferred from the lack of a stress-rate effect on strength. Mechanical proof-testing appears to be an effective method for eliminating weak samples before cell processing. 8 references.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    7
    References
    7
    Citations
    NaN