Biomass control in a fixed-bed anaerobic reactor
1989
Abstract In order to improve the reliability of fixed-bed anaerobic reactors, the effects of a media and biomass control method were studied using bench scale equipment and mathematical simulation. Test results showed that the allowable volumetric loading rates (kg COD/m 3 ·d) were directly proportional to the packed ratio of the media. Although a reactor completely filled with media (packed media ratio: 100%) could handle an 80% reduction in COD at a loading rate of 11 kg COD/m 3 ·d, a packed reactor half-filled with media (packed media ratio: 50%) could not handle more than 5.5 kg COD/m 3 ·d to achieve the same degree of reduction in COD. Simulation results were based on actual commercial plant operation and showed a practical correlation between COD removal and effective void volume ratio. To achieve a steady reduction of more than 80% in COD, the range of the void volume ratio was presumed to be 0.6 ∼ 0.85.