Percutaneous Microwave Ablation of Renal Tumors Using a Gas-Cooled 2.4-GHz Probe: Technique and Initial Results

2014 
Abstract The feasibility, safety, and preliminary effectiveness of microwave ablation (MWA) in the treatment of renal tumors using a high-powered, carbon dioxide–cooled probe were evaluated. There were 15 tumors treated in 14 patients. Computed tomography was performed immediately after MWA, and follow-up imaging was performed to evaluate for recurrence. Immediate technical effectiveness was 100%. One complication involved the formation of a renal artery pseudoaneurysm. At follow-up (mean interval, 12.5 wk) evaluation, 14 of 15 (93.3%) tumors demonstrated complete necrosis. MWA is a safe, effective treatment modality; larger studies are warranted to demonstrate long-term oncologic outcomes.