Evaluation of overflow wet rinsing efficiency

1994 
A description of the flow field in an overflow wafer rinse process is presented. This information is being used in an initiative whose principal objective is to reduce the usage of water in wafer rinsing. The velocity field is calculated using finite-element numerical techniques. A large portion of the water does not contribute to wafer rinsing.