Aim: The difficulty in accurately assessing coronal alignment of a total knee prosthesis (TKR) is widely accepted in the literature yet standard practice in the UK is to obtain AP and lateral knee views only; we compared standard AP knee films with long leg views of TKR in order to determine the most optimal way of assessment of the prosthetic knee alignment. Methods: We included all patients who underwent TKR between January and September 2005 at Kings College Hospital under the care of one orthopaedic consultant. We excluded 11 patients with revision surgery, augmented prosthesis, high tibial osteotomies or severe tibiotalar joint arthritis. We included 50 sets of radiographs from 48 patients (17 men and 31 women). The prostheses used were PFC (40) and Scorpio (10) and six of them were navigated and 44 were standard TKR. We compared the difference between the angle of the tibial component with the mechanical axis of the tibia in the long leg image and the angle of the prosthesis with the midline of the visualised tibia in a standard antero-posterior knee view. Statistical analysis was carried out using the student t-test. Results: The mean difference between the two views was 5.34o (range 1.9o – 12o) (p Conclusion:We concluded that the long leg views compared with the standard antero-posterior knee views provide more accurate information on the position and alignment of the tibial component of a TKR.