Improved semi-analytical simulation of UT inspections using a ray-based decomposition of the incident fields

2016 
Semi-analytical models are often used for computationally efficient ultrasonic simulations. They typically apply plane-wave or quasi plane-wave approximations to the ultrasonic fields at the location of flaws in order to calculate diffraction coefficients. In favorable cases, the plane-wave approximations used for echo computations in the Civa software yield satisfying results. However, it can lead to inaccuracies in unfavorable cases, such as for wide probe apertures, outside of the focal region, or for beam-splitting or distortion due to irregular geometries. This communication presents an improved model, implemented in a development version of the software. The new approach describes the ultrasonic field as a sum of rays and applies the plane-wave approximation to each ray instead of the entire field. It significantly improves the accuracy of echo computations. However, it implies that the diffraction is calculated for each pair of incident and diffracted rays instead of being calculated only once: a s...