Comparison of Outcomes of Percutaneous Arteriovenous Fistulae Creation by Ellipsys and WavelinQ Devices

2020 
Abstract Purpose The purpose of this study was to compare the clinical outcomes of Ellipsys with those of WavelinQ-4F percutaneous arteriovenous fistulae (pAVF) devices in a single center by a single operator. Materials and Methods A retrospective review was conducted in 100 patients who underwent pAVFs procedures (65 Ellipsys and 35 WavelinQ patients) and created between December 2017 and December 2019. A total of 69% were male and 37% were diabetic. Median age was 64.1 years (range: 28–86), and median body mass index was 27.2 (range: 15–45.1) kg/m2. A procedure sequence algorithm was followed for selecting all vascular accesses created. Results Ellipsys outcomes were compared to WavelinQ outcomes. Technical success was 100% versus 97%, respectively, and median procedure times were 14 versus 63 minutes, respectively (P Conclusions pAVFs were created with high technical success and low complications with both devices. Ellipsys pAVFs demonstrated significantly shorter procedure times without a need for radiation exposure and with superior secondary patency.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    21
    References
    18
    Citations
    NaN
    KQI
    []