Voltammetric and Amperometric Determination of Iodate using Ionic Liquid/Polyoxotungstate/MWCNTs-COOH Organic-Inorganic Nanohybrid Modified Glassy Carbon Electrode
2021
In this study, a nanohybrid modified glassy carbon electrode (GCE) was successfully fabricated with a tri-component nanocomposite consisting of (1,1'-(1,4-Butanediyl) dipyridinium) ionic liquid (bdpy), PW11O39Co(H2O) (PW11Co) polyoxometalate (POM), and carboxyl functionalized multi-walled Carbon Nanotubes (MWCNTs-COOH) by drop-casting, followed by electrodeposition technique. The morphological, electrochemical, and electrocatalytic properties of the (bdpy)PW11Co/MWCNTs-COOH/GCE were investigated by field emission scanning electron microscopy (FE-SEM) combined with energy-dispersive X-ray spectroscopy, voltammetry, and amperometry methods. The FE-SEM images well showed immobilization of (bdpy)PW11Co/MWCNTs-COOH on GCE through deformation of the mirror surface to the rough surface. The electrochemical test results confirmed that modified electrode has high stability and remarkable electrocatalytic behavior toward the reduction of iodate ion. The proposed sensor displayed two linear ranges of 10.0-200.0, and 200.0-1600.0 µmol L-1 with LOD of 27.6×10-2 µmol L-1 (S/N=3), and sensitivity of 41.0 µA mmol L-1, and 20.0 µA mmol L-1, respectively, by amperometry method. Moreover, the results of the electrochemical experiments indicated that this sensor has excellent selectivity, good reproducibility, repeatability, and analytical performance in real samples.