Comparative Value of Dobutamine and Adenosine Stress in the Detection of Coronary Stenosis With Myocardial Contrast Echocardiography

2001 
Background—Controversy continues as to whether adenosine or dobutamine is the superior pharmacological stress agent for myocardial contrast echocardiography (MCE). Methods and Results—We compared real-time MCE refilling curves and wall thickening during adenosine and dobutamine stress in 14 open-chest dogs with left anterior descending and left circumflex coronary artery stenoses that reduced hyperemia by 40% to 60% and 70% to 90% (mild and severe non–flow-limiting stenosis, NFLS) and resting flow by 10% to 30% and 35% to 50% (mild and severe flow-limiting stenosis, FLS). MCE was performed with low-energy imaging during Optison infusion. After high-energy bubble destruction, time-intensity data from risk beds were fitted for an exponential function as y=A(1−e−bt), from which the rate of intensity increase (b) and maximal plateau intensity (A) were derived. Although severe NFLS and greater stenoses decreased b with both dobutamine and adenosine, with mild NFLS it was reduced in 58% of animals with dobutami...
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    12
    References
    71
    Citations
    NaN
    KQI
    []