Efficiency Comparison of Voltage-Source and Current-Source Drive Systems for Medium-Voltage Applications
2007
This paper calculates and compares the efficiency and loss distribution in the three most popular state-of-the-art types of large motor drive systems: 1) current-source drive with active front-end rectifier; 2) current-source drive with 18-pulse thyristor rectifier; and 3) three-level voltage-source drive with 12-pulse/24-pulse diode rectifier. For converter systems with efficiencies better than 90%, it is suggested to calculate or measure the losses of all the components separately and add them up to calculate the total efficiency. A simple and accurate method of calculating switching losses for a current-source and voltage-source converter is proposed. Through the calculation and simulation of each loss factor such as switching losses, conduction losses, and snubber and filter losses, the three-level voltage-source drive system has been found to have the highest efficiency of 98.77% under the rated load of 1.6 MW.
Keywords:
- Correction
- Source
- Cite
- Save
- Machine Reading By IdeaReader
9
References
88
Citations
NaN
KQI