A Dual Triangle Timing Circuit for Improved Performance of 4-Quadrant H-Bridge Switches

2009 
Fermilab is in the process of upgrading its Booster Correction Element System to include full field correction element magnets to correct position and chromaticity throughout the booster cycle. This upgrade requires power supplies with maximum outputs of {+-}180V/{+-}65A, with current bandwidths of 5k Hz and with slew rates of min to max current in 1ms. For seamless operation around zero current and voltage, we use continuous switching on both sides of the bridge. Although the straightforward way of coordinating the switching on both sides of the bridge can be accomplished with one triangle timing wave and one voltage reference, we have found that using two triangle waves yields a switching coordination that effectively doubles the frequency of the differential ripple on the load and allows for better filtering of the output ripple.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    0
    References
    0
    Citations
    NaN
    KQI
    []