Solid-wall U-values: heat flux measurements compared with standard assumptions

2015 
The assumed U-values of solid walls represent a significant source of uncertainty when estimating the energy performance of dwellings. The typical U-value for UK solid walls used for stock-level energy demand estimates and energy certification is 2.1 Wm−2 K−1. A re-analysis (based on 40 brick solid walls and 18 stone walls) using a lumped thermal mass and inverse parameter estimation technique gives a mean value of 1.3 ± 0.4 Wm−2 K−1 for both solid wall types. Among the many implications for policy, this suggests that standard UK solid-wall U-values may be inappropriate for energy certification or for evaluating the investment economics of solid-wall insulation. For stock-level energy modelling, changing the assumed U-value for solid walls reduces the estimated mean annual space heating demand by 16%, and causes a proportion of the stock to change Energy Performance Certification (EPC) band. The analysis shows that the diversity of energy use in domestic buildings may be as much influenced by heterogeneit...