[Muscle-sparing rectus abdominis myocutaneous flap vascularized with intercostal artery perforator and inferior epigastric artery perforator for breast reconstruction].

2021 
Objective To explore the surgical technique, effectiveness, and safety of muscle-sparing rectus abdominis myocutaneous flap vascularized with intercostal artery perforator and inferior epigastric artery perforator for breast reconstruction. Methods Between December 2016 and February 2019, 6 cases of early breast cancer received modified radical surgery, lower abdominal flap was applied for one- or two-staged breast reconstruction. The average age of the patients was 34.6 years (range, 29-56 years). The disease duration ranged from 2 to 16 months, with an average of 9.5 months. The tumor was located in the upper outer quadrant in 4 cases and the lower outer quadrant in 2 cases. Pathological examination showed that they were all invasive ductal carcinoma. Four cases of breast cancer were in stage Ⅰ and 2 cases was in stage Ⅱ. During operation, the inferior epigastric artery perforators were found to be close to the upper edge of the flap and/or near the umbilical cord in 4 cases, the inferior epigastric artery perforator vessels were relatively small (<0.3 mm) in 2 cases; and the breast was reconstructed with muscle-sparing rectus abdominis myocutaneous flap vascularized with intercostal artery perforator and inferior epigastric artery perforator. The length, width, and thickness of the flap were (28.9±0.2), (12.1±0.4), and (4.4±0.3) cm, respectively. The length of the vascular pedicle was (11.5±0.2) cm and the weight of the flap was (420.5±32.7) g. Results All 6 muscle-sparing rectus abdominis myocutaneous flaps were successful, and the breast incisions healed by first intention. There was no vascular crisis, donor site effusion, hematoma, or infection. All 6 patients were followed up 12-36 months (mean, 26.8 months). The reconstructed breast had a good shape, good elasticity, and no flap contracture or deformation; only linear scars left at the donor site of the flap, and the abdominal wall function was not affected. During follow-up, there was no breast cancer recurrence and metastasis. Conclusion When the inferior epigastric artery perforators are too close to the upper edge of the flap and/or near the umbilical cord, the vascularity of lower abdominal flap can be ruined, harvested in form of muscle-sparing rectus abdominis myocutaneous flap vascularized with intercostal artery perforator and inferior epigastric artery perforator can efficiently ensure blood supply safety.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    8
    References
    0
    Citations
    NaN
    KQI
    []