Detection of Chemical Warfare Agents in the Presence of Interfering Materials

2003 
Abstract The performance of two portable chemical warfare agent (CWA) alarm units, AP2CV (Proengin France) and M90 (Environics, Finland), challenged with CWA and interfering materials, was evaluated in the laboratory. This study focuses on the effect of fuel vapors and carbon dioxide on the detectors' responses to sulfur mustard (HD) and sarin (GB) vapors. The interfering materials were chosen to simulate battlefield scenarios such as fuel spills and use of fire extinguishers. In general, CWA alarm units should have a fast and accurate response so that false negative (FN) or false positive (FP) alarm rates will be low. Although both detectors detect CWA within a few seconds, their selectivity is not the same. The false alarm rate of the AP2CV is low, suggesting that dual wavelength flame photometric detection (FPD) is a reliable technique for CWA alarm devices. The M90 is a “consumable free detector” that incorporates two sensors: atmospheric pressure chemical ionization (APCI) and semiconductor cell (SCC...
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    20
    References
    12
    Citations
    NaN
    KQI
    []