Achieving high spatial resolution and high SNR in low-field MRI of hyperpolarised gases with Slow Low Angle SHot

2013 
Abstract MRI of hyperpolarised gases is usually performed with fast data acquisition to achieve high spatial resolutions despite rapid diffusion-induced signal attenuation. We describe a double-cross k-space sampling scheme suitable for Slow Low Angle SHot (SLASH) acquisition and yielding an increased SNR. It consists of a series of anisotropic partial acquisitions with a reduced resolution in the read direction, which alleviates signal attenuation and still provides a high isotropic resolution. The advantages of SLASH imaging over conventional FLASH imaging are evaluated analytically, using numerical lattice calculations, and experimentally in phantom cells filled with hyperpolarised 3 He–N 2 gas mixtures. Low-field MRI is performed (here 2.7 mT), a necessary condition to obtain long T 2 ∗ values in lungs for slow acquisition. Two additional benefits of the SLASH scheme over FLASH imaging have been demonstrated: it is less sensitive to the artefacts due to concomitant gradients and it allows measuring apparent diffusion coefficients for an extended range of times.