모듈화 패널의 냉 · 난방에너지 저감 효과
2015
This study examines thermal insulation properties of an LEC extruded panel and a modular panel using an insulator according to the construction method. A test-bed was constructed with an external insulation system using a modular panel and an internal insulation system using the existing extruded panel, and energy consumption was measured in a maintenance condition at an indoor temperature of 20℃. As a result of the experiment, energy consumption was 14% lower in the outside insulation system using a modular panel than in the internal insulation system.
Keywords:
- Correction
- Source
- Cite
- Save
- Machine Reading By IdeaReader
0
References
0
Citations
NaN
KQI