Head-to-head validation of six immunoassays for SARS-CoV-2 in hospitalized patients.

2021 
Abstract Background Detecting SARS-CoV-2 antibodies may help to diagnose COVID-19. Head-to-head validation of different types of immunoassays in well-characterized cohorts of hospitalized patients remains needed. Methods We validated three chemiluminescence immunoassays (CLIAs) (Liaison, Elecsys, and Abbott) and one single molecule array assay (SIMOA) (Quanterix) for automated analyzers, one rapid immunoassay RIA (AllTest), and one ELISA (Wantai) in parallel in first samples from 126 PCR confirmed COVID-19 hospitalized patients and 158 pre-COVID-19 patients. Specificity of the AllTest was also tested in 106 patients with confirmed parasitic and dengue virus infections. Specificity of the Wantai assay was not tested due to limitations in sample volumes. Results Overall sensitivity in first samples was 70.6 % for the Liaison, 71.4 % for the Elecsys, 75.4 % for the Abbott, 70.6 % for the Quanterix, 77.8 % for the AllTest, and 88.9 % for the Wantai assay, respectively. Sensitivity was between 77.4 % (Liaison) and 94.0 % (Wantai) after 10 dpso. No false positive results were observed for the Elecsys and Abbott assays. Specificity was 91.1 % for the Quanterix, 96.2 % for the Liaison, and 98.1 % for the AllTest assay, respectively. Conclusion We conclude that low sensitivity of all immunoassays limits their use early after onset of illness in diagnosing COVID-19 in hospitalized patients. After 10 dpso, the Wantai ELISA has a relatively high sensitivity, followed by the point-of-care AllTest RIA that compares favorably with automated analyzer immunoassays.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    29
    References
    1
    Citations
    NaN
    KQI
    []