Operational limits in vibration diagnostics

2016 
The paper discusses some practical problems occurring at ISO 10816-1 application in technical practice. Technical diagnosticians find out frequently that the zone boundaries proposed by the standard are not sensitive adequately to the changes in vibrations during operation resulting from a change of technical condition of the machine. The principle of statistical determination of individual operational limits from the measured overall level of RMS vibration velocity (overall level) with utilization of statistical regulation of individual values is also described in the paper. The alarm limit for the overall level (boundary between the B and C zones) in the range 10–1000 Hz is specified in the paper on the basis of measuring of vibrations on the electric motor of Bosch Rexroth hydraulic unit.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    1
    References
    1
    Citations
    NaN
    KQI
    []