Complications associated with traction on the hip during arthroscopy

2004 
We studied 16 hips (eight cadaver specimens) using arthrography, arthroscopy and anatomical dissection, under incremental traction of up to a maximum of 64 kg, to determine the relationship of the portals to nearby neurovascular structures. The distance of each arthroscopic portal (anterior, anterolateral, and posterolateral) to the associated neurovascular structures was measured after the application of 23 kg of traction. Traction of up to 64 kg on the lower limb failed to produce evidence of labral or capsular injury. Furthermore, traction of 23 kg resulted in little change in the position of adjacent neurovascular structures relative to the standard arthroscopic portals.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    19
    References
    35
    Citations
    NaN
    KQI
    []