A new method for detecting electromigration failure in VLSI metallization

1984 
A method has been developed for metallization lifetime predictions using a continuous resistance monitoring technique. A useful lifetime criteria, based upon measured resistance changes, has been determined that is more sensitive and, consequently, more accurate than present catastrophic failure techniques.