Comparison of Measured Particle Lung-Deposited Surface Area Concentrations by an Aerotrak 9000 Using Size Distribution Measurements for a Range of Combustion Aerosols

2013 
Surface area in addition to mass concentration is increasingly being emphasized as an important metric representing potential adverse health effects from exposure to inhaled particles. Lung-deposited surface area (SA) concentrations for a variety of aerosols: coal, biomass, cigarette, incense, candle, and TiO2 were measured using an AeroTrak 9000 (TSI Incorporated) and compared with those calculated from number size distributions from a scanning mobility particle sizer (SMPS). Three methodologies to compute the SA concentrations using the International Commission on Radiological Protection's (ICRP) Lung Deposition model and an SMPS were compared. The first method calculated the SA from SMPS size distributions, while the second method used lognormal size distribution functions. A third method generated a closed-form equation using the method of moments. All calculated SMPS SA data against which the measured SA data were compared were generated using the first method only; however, the SA concentrations cal...