Considerations for post-lethality treatments to reduce Listeria monocytogenes from fully cooked bologna using ambient and pressurized steam

2005 
Abstract During processing of ready-to-eat (RTE) deli meats, any secondary processing procedures such as peeling and cutting introduce the distinct possibility of cross-contamination between equipment, personnel, and food. To eliminate or reduce pathogens such as Listeria monocytogenes and ensure food safety, RTE deli meats can be pasteurized prior to or after packaging. In this study, ambient steam in-package pasteurization was compared with pressurized steam prepackaging pasteurization to reduce L. monocytogenes from fully cooked RTE bologna. The bologna (14 cm diameter×1.5 cm thickness) samples were surface-inoculated to contain about 8 log 10 of L. monocytogenes . To achieve 2 log reductions for L. monocytogenes , the bologna samples needed to be treated for about 10 s in pressurized steam at 131 °C or for about 2.5 min in ambient steam at 100 °C. The pasteurization time using pressurized steam treatment was about 75–90% shorter than using ambient steam treatment. Pressurized steam treatment may be integrated into a vacuum packaging unit to effectively eradicate L. monocytogenes from RTE meats just prior to sealing the retail packages to further reduce the treatment time, avoid post-treatment recontaminations by pathogens, and improve food safety without detrimentally affecting meat quality.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    20
    References
    19
    Citations
    NaN
    KQI
    []