Dose Analysis on High Performance Vault Storage System of Spent Nuclear Fuel

2000 
The radiation shielding design for the high performance vault storage system is studied in order to satisfy the design targets at the controlled area and the site boundaries. The additional gamma-ray shields in front of the storage tubes and the shielding structures at the entrance of the ducts are installed. The dose rates at the inlet and the outlet of the ducts are estimated by 3D calculation. And the dose rates at the controlled area and the site boundaries are evaluated taking the effect of the direct radiation and the indirect one (skyshine) into consideration. The dose rates at the controlled area and the site boundaries are about 7×10-7 Sv/h and 3×10-10 Sv/h, respectively. Thus, we have the prospect to satisfy the design targets.