Pharmacometric Analysis of IgPro10 in Japanese and Non-Japanese Patients With Primary Immunodeficiency

2020 
Abstract Purpose Immunoglobulin (Ig) G replacement therapy, administered intravenously (IVIG) or subcutaneously (SCIG), is the standard treatment in patients with primary immunodeficiencies (PID). We aimed to characterize the pharmacokinetic (PK) characteristics of serum IgG following administration of IgPro10 every 3 or 4 weeks in Japanese patients with PID, and compare with PK in non-Japanese patients. A previously developed population PK (PPK) model was validated, and predicted parameters were compared with the results from the clinical study. Methods The previously developed PPK model, containing IgG concentration data from 5 non-Japanese studies, was supplemented with data from 3 Japanese studies of IgPro10 or IgPro20 to compare the IgG PK parameters between Japanese and non-Japanese patients. The model was externally validated by simulating IgG concentration–time profiles in Japanese patients to predict serum IgG PK characteristics and to compare them with observed Japanese PK data from Study IgPro10_3004. Findings The analysis included 4502 serum IgG concentration values (from 34 Japanese and 168 non-Japanese patients). PPK estimates from the current analysis demonstrated a clearance (CL) of 0.139 L/d, central volume (V2) of 4.01 L, inter-compartmental clearance (Q) of 0.30 L/d, and peripheral volume of 3.51 L. These results were consistent with those from the previously published PPK model, with similar bootstrap means and 95% CIs. Goodness-of-fit criteria indicated that the final PPK model was consistent with observed data, with no systemic bias in model prediction. Prediction-corrected visual predictive checks confirmed a good description of data on both SCIG and IVIG. PK parameters were equivalent between Japanese and non-Japanese patients. Body weight was determined to be a significant covariate on both CL and V2. Simulated and observed AUC and maximum and minimum serum IgG concentrations were similar, with 90% CIs overlapping between simulated and observed IgG concentrations in Japanese patients. Implications PK parameter estimates of serum IgG were similar between Japanese and non-Japanese patients with PID. The PPK model, updated with Japanese data, was consistent with the previously published PPK model and could accurately predict both individual and population serum IgG concentration–time profiles following IgPro10 IV infusions every 3 or 4 weeks. EudraCT identifier: 2016-001631-12.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    33
    References
    3
    Citations
    NaN
    KQI
    []