A new neutron monitor with silver activation

2010 
Abstract A moderator-type neutron monitor has been developed, which registers delayed beta rays from neutron-induced silver activation and which is able to measure dose equivalent in pulsed fields with peak dose rates of several thousand Sv h −1 . The monitor uses four silicon diodes in the centre of a polyethylene moderator, 30 cm in diameter. Two of the diodes are covered by natural silver foils and two of them by tin foils. The latter are used to subtract photon-induced pulses. For registering signals, a pulse height threshold is set at 662 keV, which minimizes the effect of 137 Cs and lower energy radiation and – in addition – enhances the detection of beta rays from the shorter half-life silver isotope 110 Ag (25 s) as compared to the longer half-life isotope 108 Ag (144 s). The results of measurements in neutron and photon calibration fields, of MCNPX neutron response calculations and of first measurements in a high-intensity pulsed field at the PSI accelerator are shown.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    8
    References
    7
    Citations
    NaN
    KQI
    []