Application of stratified implantation for silicon micro-strip detectors

2015 
In the fabrication of a 48 mm x48 mm silicon micro-strip nuclear radiation detector with 96 strips on each side, a perfect P-N junction cannot be formed consistently by the one-step implantation process, and thus over 50% of strips produced do not meet application requirements. However, the method of stratified implantation not only avoids the P region between the surface of wafers and the P+ region, but also overcomes the shadow effect. With the help of the stratified implantation process, a perfect functional P-N junction can be formed, and over 95% of strips meet application requirements.