Variation in Positive End-Expiratory Pressure Levels for Mechanically Ventilated Extremely Low Birth Weight Infants

2017 
Objective To test the hypothesis that significant positive end-expiratory pressure (PEEP) level variation exists between neonatal centers. Study design We performed a secondary analysis cohort study of the Nasal Intermittent Positive-Pressure Ventilation trial. Our study population was extremely low birth weight infants requiring mechanical ventilation within 28 days of life. The exposure was neonatal center; 34 international centers participated in the trial. Subjects from centers with fewer than 5 eligible cases were excluded. The main outcome was the maximal PEEP level used during the first course of mechanical ventilation. Infant characteristics judged a priori to directly influence clinical PEEP level selection and all characteristics associated with PEEP at P Results A total of 278 extremely low birth weight infants from 17 centers were included. Maximal PEEP ranged from 3 to 9 cm H 2 O, mean = 5.7 (SD = 0.9). Significant variation between centers remained despite adjustment for infant characteristics ( P Conclusions Marked variation in PEEP levels for extremely low birth weight infants exists between neonatal centers. Research providing evidence-based guidance for this important aspect of respiratory care in preterm infants at high risk of lung injury is needed. Trial registration ClinicalTrials.gov : NCT00433212 .
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    19
    References
    4
    Citations
    NaN
    KQI
    []