Parametric evaluation of the aerodynamic performance of an annular combustor-diffuser system

1990 
This study experimentally determined the effects of dominant geometric and flow parameters on the aerodynamic performance of an annular combustor-diffuser system. For each parametric configuration, data were obtained at 13 different flow rates through the inner annulus, outer annulus, and combustor dome. The parametric effects investigated included the dump gap dimension, flow splits, prediffuser inlet velocity profile, and combustor channel height. During these measurements, the average prediffuser inlet Mach number was 0.305. The measured static pressure recovery coefficient and the total pressure loss coefficient in the prediffuser as well as the overall system are presented in this paper. The study found that the performance of the combustor-diffuser system improves with increasing dome flow rate or dump gap dimension.