Advanced high-explosive flux compression generator development: The CN-III series

1992 
A very successful series of three flux compression generator (FCG) experiments and one hydro-only test, designed to quantify the performance capabilities and limitations of high-current, high-field, high-power coaxial FCGs, is reported. In the last test, the CN-III FCG produced a peak current of >150 MA with a final doubling time of <10{mu}s into a 2-nH inductive load. Experimental results are in excellent agreement with extensive preshot and postshot one-dimensional (1D) and two-dimensional (2D) magnetohydrodynamic (MHD) calculations.