The first reported aspiration thrombectomy with a guide extension mother-and-child catheter in ST elevation myocardial infarction due to bacterial vegetation coronary artery embolism

2016 
A 74-year-old man presented with ST elevation myocardial infarction (STEMI) on the 15th day of antibiotic therapy due to aortic valve staphylococcal endocarditis. The coronary angiography revealed occlusion of the left anterior descending artery (LAD) (Figure 1 A). Initial aspiration thrombectomy (AT) with an Export AP (Medtronic Vascular) catheter reestablished TIMI 3 flow. No trace of ruptured plaque was detected. However, the final contrast injection revealed occlusion of the left circumflex artery (LCx) (Figure 1 B), presumably by material translocated during withdrawal of the AT device. Since AT using the Export AP catheter was ineffective in the LCx, a guide extension mother-and-child catheter was applied as an aspiration device [1]. First a 2.0 × 20 mm balloon catheter was inflated beyond the site of the occlusion in order to ensure protection from distal embolism and facilitate the guide extension catheter advancement (Figure 1 C). Subsequently, the Heartrail II-ST01 5 Fr (Terumo Medical) catheter was positioned proximal to the site of the occlusion (Figure 1 C). Aspiration was performed with suction pressure generated by a 20 cc syringe attached to the proximal tip of the guide extension catheter via a y-connector, while the guide wire and balloon catheter remained at their positions. The large body of the embolus was pulled into the syringe (Figure 1 E), which resulted in TIMI 3 flow restoration (Figure 1 D). The patient's further clinical course was uneventful. Histological examination of the aspirated material revealed thrombus with purulent foci, the picture suggestive of bacterial vegetation (Figure 1 F). Figure 1 A – Initial angiography, the site of the LAD occlusion (thin arrow) and the patent LCx. B – The site of the LCx occlusion by the material translocated from the LAD during aspiration thrombectomy using the Export AP (thin arrow). C – ... The greatest shortcoming of the dedicated aspiration catheters is their small inner cross-sectional area (CSA). The suction power is often insufficient to evacuate occlusive material, but intracoronary maneuvers may fragment it; therefore, distal embolization of the infarct related artery is a frequently reported complication [2]. Furthermore, a large thrombus or bacterial vegetation may get stuck at the tip of an aspiration device and be released during its withdrawal, causing embolic stroke or occlusion of another artery. Frequently, the radial artery may not accommodate guide catheters larger than 6 Fr, which precludes the use of larger dedicated AT devices. Previously, in selected cases of STEMI, wherein a large thrombus not amenable to routine AT was identified, aspiration using a deeply advanced guide catheter or a ‘Fogarty type’ balloon embolectomy has been attempted. These approaches provide the potential for coronary dissections and prolonged ischemic times [3, 4]. Mechanical thrombectomy might also be considered; however, these devices are rarely available “off the shelf”. Therefore, AT with guide extension catheters seems the reasonable option. Beside the Heartrail II-STO1 catheter, the GuideLiner (Vascular Solutions) and the Guidezilla (Boston Scientific) catheters may be similarly used for aspiration [5]. The Heartrail II-STO1 catheter is a 120 cm straight tip 5 Fr catheter that extends throughout the length of the 6 Fr guide catheter, unlike the other two guide extension catheters. Distal protection by balloon occlusion does compromise the inner CSA, possibly limiting the efficacy of AT. An optional approach for distal protection would be a filter wire basket, less likely to compromise the inner CSA of the AT device.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    0
    References
    3
    Citations
    NaN
    KQI
    []