Visual Outcomes After Implantation of Allogenic Lenticule in a 100-µm Pocket for Moderate to High Hyperopia: 2-Year Results.

2021 
Purpose To investigate 2-year visual outcomes, stability, and predictability after allogenic lenticule implantation in a 100-µm pocket for moderate to high hyperopia correction. Methods In this prospective case series, 14 eyes of 9 patients with moderate to high hyperopia ranging from +3.00 to +8.00 diopters sphere were included between March and September 2018. Allogenic lenticules extracted from myopic small incision lenticule extraction were implanted into a pocket created by femtosecond laser at a 100-µm depth in recipients with hyperopia. All patients were followed up for 2 years. Uncorrected (UDVA) and corrected (CDVA) distance visual acuity, manifest refraction, corneal topography, Fourier-domain optical coherence tomography, and in vivo confocal microscopy were examined. Results At postoperative 2 years, 2 eyes (14.3%) gained one line of CDVA, 11 eyes (78.6%) had unchanged CDVA, and 1 eye (7.1%) lost one line of CDVA. No eyes lost two or more lines of CDVA. Twelve of the treated eyes (85.7%) had postoperative uncorrected near visual acuity equal to or better than pre-operative values. The spherical equivalent decreased from +5.53 ± 1.45 D preoperatively to -0.60 ± 1.20 D at postoperative year 2 (P Conclusions The findings suggest that allogenic lenticule transplantation may be a promising option for the correction of moderate to high hyperopia. [J Refract Surg. 2021;37(11):734-740.].