Removal of Root Canal Fillings in Curved Canals Using Either Reciprocating Single- or Rotary Multi-instrument Systems and a Supplementary Step with the XP-Endo Finisher

2016 
Abstract Introduction This study compared the efficacy of a reciprocating single-instrument system and a rotary multi-instrument system followed by a supplementary approach with a finishing instrument in removing the filling material from curved canals during retreatment. Methods Forty mesial canals from extracted mandibular molars were instrumented and filled. Then, each mesial canal was retreated by using either Reciproc (VDW, Munich, Germany) or Mtwo (VDW) instruments, alternating the technique used per canal from root to root. The working time was recorded, and the percentage of removed filling volume was assessed by means of micro–computed tomography imaging before and after retreatment. Canals still showing filling material remnants were subjected to an adjunctive approach with the XP-Endo Finisher (FKG Dentaire, La Chaux-de-Fonds, Switzerland), and another microCT scan was taken. Data were statistically analyzed with a significance level of 5%. Results The percentage of filling material removed with Mtwo instruments (96%) was significantly higher than Reciproc (89%) ( P P P P Conclusions The rotary multiple-instrument system was more effective and faster than the reciprocating single-instrument approach in removing previous root canal fillings. As for the Reciproc group, it was observed that the larger instrument promoted significantly better results. The adjunctive finishing instrument XP-Endo Finisher significantly improved filling material removal.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    32
    References
    70
    Citations
    NaN
    KQI
    []