Environmental Monitoring and Evaluation of the X-Ray Field Flaw Inspection Workplace in a Factory Building

2019 
The surrounding radiation environment of the field flaw detection workplace has been theoretically calculated and monitored on site when an industrial X-ray flaw detector in a factory building is operated during the field flaw detection. The results show that when 5mA tube current and 250 kV tube voltage penetrate the steel tube at the thickness of 16mm twice, the calculated value of the air kerma rate at the inspection point is basically consistent with the measured value. Additionally, the boundary of the controlled area and the supervised area corresponded to the measured value along the main beam direction belongs to the wall in the east of the workshop. The calculated distances of the leaking beam corresponding to the boundary of the controlled area and the supervised area of the calculated value should be 19m and 58m, respectively. The minimum and maximum distances of the controlled area of the measured value are 13m and 17m, respectively; while the maximum and minimum distances of the supervised area of the measured value are 31m and 36m, respectively, both areas are within the workshop. Meanwhile, annual effective doses that might be accepted by professionals and the public have been estimated.