An evaluation of Technegas as a ventilation agent compared with krypton-81 m in the scintigraphic diagnosis of pulmonary embolism

1992 
A ventilation agent that provides good quality lung images, which is cheap, easy to use and non-toxic, with a low radiation dose, has long been sought. Technegas, an ultrafine aerosol of technetium-99m-labelled carbon, was developed with these qualities in mind. We have studied Technegas in a clinical setting to evaluate some of these qualities. Twenty-five patients referred with a diagnosis of suspected pulmonary embolism were investigated during the same study using both krypton-81m and Technegas as ventilation agents in conjunction with99mTc-macroaggregated albumin as a perfusion agent. Technegas provided images which were of satisfactory quality. Images were obtained relatively easily and without discomfort to the patient, and Technegas has the advantage of always being available. A semi-quantitative regional assessment was employed which showed a good correlation (r = 0.499, P <0.001) between Technegas and krypton-81 m ventilation. We report on an effect not previously found to be significant, that is lung regions were better ventilated with Technegas than with krypton-81 m. This altered the diagnostic probability rating of pulmonary embolism in a number of patients (n = 3, 12%) compared with krypton-81 m. This effect was also noted in a further 8 patients (32%) without a change in the diagnostic probability. We offer possible explanations for this phenomenon.