A differential pumping system to temporarily seal a leaking, rotatable ConFlat flange

2018 
Abstract A differential pumping system was developed to seal a vacuum leak located between a rotatable ConFlat flange and a section gate valve (SGV). This system can create a vacuum surrounding and isolating the leaking area so as to reduce the leak rate across the leaking paths by four orders of magnitude. Such a differential pumping system has been used in the TLS storage ring (SR) vacuum systems to seal this leak and the beam lifetime could thereby be improved from 350 to 430 min at 360 mA.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    8
    References
    1
    Citations
    NaN
    KQI
    []