Regularization control on designing and constructing for HTR 10

1998 
The paper discusses on the necessity of carrying out regularization control in designing and constructing the 10MW high temperature gas cooled reactor (HTR 10), from the requirement of nuclear safety, of technical feasibility, of economical feasibility and accumulating developmental experiences. This paper expounds taking some effective measures in the practice of carrying out regularization control on HTR 10. These measures include laying down design control procedures, working out HTR 10 design criteria according to current codes and standards, carrying on regularization design, regularization control of design documents and drawings, and according to quality assurance programs and procedures carrying on regularization control, for ensuring engineering progress and quality. It has universality for regularization control of nuclear engineering projects design and construction. This paper also provides some beneficial use of reference for later nuclear engineering design and construction.