Spherical wire arrays electrical explosion in water and glycerol

2017 
The results of experiments and one-dimensional (1D) hydrodynamic (HD) simulations of electrical explosions of spherical Cu wire arrays in water and glycerol for various stored energy of the pulse generator and sphere diameters are presented and discussed. It was found that the convergence of the shock wave generated by an exploding spherical wire array in glycerol is significantly faster than in water. The resulting pressure in the vicinity of the implosion center is several times larger in glycerol than in water. Increasing the initially stored energy from 3.6 to 6.1 kJ (for identical array diameters) or decreasing the sphere diameter from 30 to 20 mm (for identical stored energy) leads to an increase in the pressure, temperature, and density in the vicinity of the implosion center. The pressure in a spherical volume of ∼0.2 mm in diameter at the origin of the sphere is estimated by 1D HD simulations to be in excess of 1012 Pa.