Cardiovascular Evaluation of Electronic Control Device Exposure in Law Enforcement Trainees: A Multisite Study
2010
OBJECTIVE: Occupational health risk with regard to training exercises is a relatively under studied domain for law enforcement officers. One potential health risk is exposure to electronic control devices (ECDs). METHODS: Seven different training facilities in six states participated. Law enforcement trainees (N = 118) were exposed to Taser International's (Scottsdale, AZ) X26 for up to 5 seconds. RESULTS: There was no evidence of cardiac or skeletal muscle breakdown. Exposure did not adversely affect electrocardiogram (ECG) morphology obtained 24 hours after exposure in 99 trainees. For two trainees with preexisting ECG abnormalities, ECG morphology differed in the post-ECD samples. CONCLUSIONS: The results from this large, multisite study suggest that, for most trainees, ECD exposure does not represent a significant health risk. Further investigation is warranted for cardiac vulnerability and potential interactions with ECD exposure. Language: en