Fabrication of Bismuth Absorber Arrays for NTD-Ge Hard X-ray Microcalorimeters

2020 
The high-spectral-resolution detection of hard X-rays (E > 20 keV) is a challenging and nearly unexplored area in space astrophysics. Traditionally hard X-ray detectors present moderate spectral resolutions, although few tens of eV one could open new frontiers in the study of nuclear processes and high-temperature plasma dynamics in energetic processes. This can be achieved by using cryogenic microcalorimeters. Within a research activity aimed at developing arrays of neutron transmutation-doped germanium (NTD-Ge) microcalorimeters for the high-spectral-resolution detection (about 50 eV@60 keV) of hard X-rays (20 keV   60 μm) bismuth absorber arrays. The adopted technological process and the study of related process parameters are discussed; preliminary results on produced arrays are given.