Development of a new peptide-bead coupling method for an all peptide-based Luminex multiplexing assay for detection of Plasmodium falciparum antibody responses.

2021 
Abstract Using a recombinant protein antigen for antibody testing shows a sum of antibody responses to multiple different immune epitopes existing in the protein antigen. In contrast, the antibody testing to an immunogenic peptide epitope reflects a singular antibody response to the individual peptide epitope. Therefore, using a panel of peptide epitopes provides an advantage for profiling multiple singular antibody responses with potential to estimate recent malaria exposure in human infections. However, transitioning from malaria immune epitope peptide-based ELISA to an all peptide bead-based multiplex Luminex assay presents some challenges including variation in the ability of different peptides to bind beads. The aim of this study was to develop a peptide coupling method while demonstrating the utility of these peptide epitopes from multiple stage antigens of Plasmodium falciparum for measuring antibodies. Successful coupling of peptide epitopes to beads followed three steps: 1) development of a peptide tag appended to the C-terminus of each peptide epitope consisting of beta-alanine–lysine (x 4)--cysteine, 2) bead modification with a high concentration of adipic acid dihydrazide, and 3) use of the peptide epitope as a blocker in place of the traditional choice, bovine serum albumin (BSA). This new method was used to couple 12 peptide epitopes from multiple stage specific antigens of P. falciparum, 1 Anopheles mosquito salivary gland peptide, and 1 Epstein-Barr virus peptide as an assay control. The new method was applied to testing of IgG in pooled samples from 30 individuals with previously repeated malaria exposure in western Kenya and IgM and IgG in samples from 37 U.S. travelers with recent exposure to malaria. The new peptide-bead coupling method and subsequent multiplex Luminex assay showed reliable detection of IgG to all 14 peptides in Kenyan samples. Among 37 samples from U.S. travelers recently diagnosed with malaria, IgM and IgG to the peptide epitopes were detected with high sensitivity and variation. Overall, the U.S. travelers had a much lower positivity rates of IgM than IgG to different peptide epitopes, ranging from a high of 62.2% positive for one epitope to a low of only 5.4% positive for another epitope. In contrast, the travelers had IgG positive rates from 97.3% to 91.9% to various peptide epitopes. Based on the different distribution in IgM and IgG positivity to overall number of peptide epitopes and to the number of pre-erythrocytic, erythrocytic, gametocytic, and salivary stage epitopes at the individual level, four distinct patterns of IgM and IgG responses among the 37 samples from US travelers were observed. Independent peptide-bead coupling and antibody level readout between two different instruments also showed comparable results. Overall, this new coupling method resolves the peptide-bead coupling challenge, is reproducible, and can be applied to any other immunogenic peptide epitopes. The resulting all peptide bead-based multiplex Luminex assay can be expanded to include other peptide epitopes of P. falciparum, different malaria species, or other diseases for surveillance, either in US travelers or endemic areas.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    61
    References
    0
    Citations
    NaN
    KQI
    []