Investigations on Ni-Ti-Al Ohmic Contacts Obtained on P-Type 4H-SiC

2012 
Transfer Length Method (TLM) based-structures were fabricated on 0.8 µm-thick epitaxial p-type Silicon Carbide (4H-SiC) layers. TLM mesas were defined by a 2 µm height using an SF6/O2 reactive ion etching. TLM metal patterns were obtained by a lift-off procedure and electron beam deposition of Ni, Ti, Al and Pt. The patterned samples were annealed in Argon ambient at temperature ranging from 700°C up to 1000°C in a RTA furnace with a rapid heating ramp (up to 50°C/s) to complete the ohmic contact with the p-type SiC layer. Specific contact resistances were extracted from current/voltage measurements. To identify and follow the profile evolution of constituting element in the contacts and at the SiC/contact interface, the ohmic contacts were characterized using Secondary Ion Mass Spectrometry and Energy-Dispersive X-Ray spectroscopy before and after annealing. Ohmic contacts are obtained only for the Ni/Ti/Al and Ni/Ti/Al/Ni stacking layers and not for the Ti/Al/Ti/Ni and Ti/Al/Ti/Pt/Ni compositions. The specific contact resistance of Ni/Ti/Al/Ni stacking layers was observed to decrease from 2.7×10-4 Ω.cm2 at 700°C and 6.3×10-5 Ω.cm2 at 750°C to a minimal value of 1.5×10-5 Ω.cm2 at 800°C. Ohmic contacts are obtained with a reproducibility of 80 %.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    13
    References
    10
    Citations
    NaN
    KQI
    []