Electromyographic endotracheal tube placement during thyroid surgery in neuromonitoring of recurrent laryngeal nerve

2011 
Abstract Intraoperative neuromonitoring (IONM) is widely used in thyroid surgery. This study aimed to investigate the influence of neck extension on electromyographic (EMG) endotracheal tube displacement and to determine the necessity of routinely checking the final electrode position after the patient had been fully positioned. A consecutive 220 patients undergoing thyroidectomy were enrolled. All patients were intubated with the EMG endotracheal tube under direct laryngoscopy. The electrode position and tube displacement were routinely checked and measured by laryngofiberoscopy before and after patient positioning. The patients were divided into two groups. In Group I ( n  = 110), the EMG tube was taped and fixed to the right mouth angle before full neck extension. In Group II ( n  = 110), the EMG tube was disconnected from the circuit tube and was not taped until full neck extension. In all patients, we ensured that the final electrode position was the optimal position with laryngofiberoscopic examination. The tube displacement after neck extension ranged from 16 mm upward to 4 mm downward in Group I and from 12 mm upward to 5 mm downward in Group II. The rate of tube displacement greater than 10 mm was 12.7% in Group I and 3.6% in Group II. Successful monitoring was achieved in all patients after the final optimal position of electrodes was ensured routinely. The electrode position can be severely displaced after the patient has been fully positioned. Verification of ideal position of electrodes before the beginning of the operation is a necessary step to guarantee functional intraoperative neuromonitoring.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    21
    References
    44
    Citations
    NaN
    KQI
    []