Closure of an unusual morphology patent ductus arteriosus with a covered stent in a dog

2020 
Abstract Patent ductus arteriosus (PDA) with unusual morphology was diagnosed in a 3-year-old German Shepherd presented for exercise intolerance. Two interventional PDA closure procedures with various Amplatzer devices and one surgical ligation were attempted in order to close the PDA. However, PDA closure failed with both methods due to the unusual morphology and the severe enlarged ductus ampulla. Therefore, the patient underwent an aortic covered stent placement and successful closure of the PDA was achieved. Eight months after the procedure the dog was free of clinical signs and no residual flow was identified through the PDA on transthoracic echocardiography. Moreover, computed tomography angiography demonstrated correct stent positioning, with no evidence of thrombus formation, damage to the stent, nor any aortic wall abnormalities. Aortic covered stent placement is a viable option in dogs with unusual PDA morphology.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    23
    References
    1
    Citations
    NaN
    KQI
    []