Principles, operations, and expected performance of the LISA Pathfinder charge management system

2009 
The test masses of LISA Pathfinder are free flying and therefore not grounded to the spacecraft by a wire. Because of galactic cosmic rays, solar energetic particles, and unknown microscopic surface effects during initial test mass release, an unacceptable level of absolute charge might be present on the test masses. A charged test mass can endanger transition to high accuracy control modes which are required for science experiments. Furthermore, charged test masses introduce unwanted disturbance accelerations for example due to Coulomb interactions with surrounding conducting surfaces. The charge management system is designed to discharge the test masses up to a tolerable level of absolute charge such that the mission goal can be achieved. It is therefore an essential part of the experiments to be performed with the LISA Technology Package. The paper describes charge management tasks to be performed on board the spacecraft and summarizes the principles of charge measurement and discharge control. An overview of the experiment operations is given where the interconnection of operational charge management system modes and operational modes of the drag-free, suspension and attitude control system is considered. Simulated performance results are presented.