Estimation of voltage and current distortions in the power system supplying the AC arc furnace

2011 
The paper presents a circuit model of three phase arc arrangement, taking into account the nonlinearity of the arc appearing In the particular phases as well as the windings vector groups of a furnace transformer. This model was designed on the ground of parameters, resulting from a voltage current characteristic of the arc. At modeling of changes of parameters of an arc we applied the random values of resistance. The values of higher harmonics of current and voltage for each considered case have been evaluated by using the simulation program MicroCap - 8. In the paper we have included the exemplary results of numerical calculations. Streszczenie W artykule przedstawiono model obwodowy trojfazowego urządzenia lukowego z uwzglednieniem nieliniowości luku w poszczegolnych fazach oraz grupy polączen transformatora piecowego. Model ten opracowano na podstawie parametrow wynikających z nieliniowej charakterystyki napieciowo - prądowej luku. Do symulacji zmian parametrow luku elektrycznego wykorzystano generator zmienny losowo. Wszystkie obliczenia zostaly przeprowadzone w programie MicroCap - 8. Obliczono wartości wyzszych harmonicznych prądu i napiecia w odbiorniku oraz po stronie pierwotnej i wtornej transformatora piecowego. Zamieszczono przykladowe rezultaty obliczen numerycznych. (Znieksztalcenia napiecia i prądu w ukladzie zasilania pieca lukowego)