Method Development and Validation of Candesartan cilexetil by RP-HPLC

2012 
A simple, rapid and precise and accurate RP-HPLC method was developed for the estimation of candesartan. The method involves a simple technique using paracetamol as internal standard. HPLC separation was achieved using C18 Intersil column (256 x 4.6 id) with an isocratic mobile phase composed of selected acetonitrile: methanol [40:60 % v/v. pH 6.0] at a flow rate of 1.0 mL/min with UV detection was performed at 228 nm. The retention time of candesartan and internal standard was found to be 1.96 and 3.33 min respectively. The assay was validated for the parameters like accuracy, precision, robustness and system suitability parameters. The method was validated over a linear test concentration range of 80-120%. The recovery of the method was in between 99.0-101.0%. The proposed method was found to be accurate, precise, selective and rapid and it can be useful in the routine analysis for the determination of candesartan cilexetil in pharmaceutical dosage form.