Accurate measurement of electrical bulk resistivity and surface leakage of CdZnTe radiation detector crystals

2006 
A classical method for the accurate measurement of the bulk resistivity and a quantitative separation of bulk and surface leakage currents in semi-insulating CdZnTe radiation detectors is evaluated. We performed an extensive set of experiments on CdZnTe single-crystal test devices to confirm the reliability and reproducibility of the measurements and the validity of the underlying assumptions for data analysis and parameter extraction. The experiments included temperature dependent dual current-voltage measurements on devices with guard electrodes as a function of device thickness, surface preparation, surface passivation, and electrode deposition conditions. We also evaluated the temperature dependence of the bulk resistivity and implemented a general temperature normalization routine to allow a reliable comparison between various crystal samples.