National intercomparisons of 131I radioactivity measurements in nuclear medicine centres in India.

2003 
Abstract National intercomparisons of activity measurements of 131 I, a radioisotope widely used for diagnosis and therapy of thyroid related ailments, were initiated in 1979 as a quality assurance program, towards improving radiation safety procedures and related dosimetry in Nuclear Medicine Centres (NMCs) in India. Oral administration of a known quantity of radioiodine to patients requires accurate radioactivity measurements to be performed on a well-calibrated isotope calibrators. Under or over estimation of the activity due to a faulty or uncalibrated isotope calibrator could provide misleading results. Calibration of isotope calibrators and the traceablity of subsequent measurements to the national standards laboratory is one of the essential basic radiation safety requirement of the IAEA. In view of the stringent quality assurance requirements for activity measurements imposed by Atomic Energy Regulatory Board, a National Intercomparison Program was initiated and to date ten such intercomparison programs have been conducted by the Radiation Safety Systems Division, of the Bhabha Atomic Research Centre. This program has benefited the participants by making their measurements traceable to the National Primary Standards. Over the years there has been a marked increase in the number of NMCs participating in the intercomparison programs. As a result, the number of institution showing large deviation from the correct value has decreased considerably over the years. This program thus, has enabled participating NMCs to check their isotope calibrators so as to ensure proper delivery of radiation dose to the patients and hence to optimise patient exposure.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    5
    References
    17
    Citations
    NaN
    KQI
    []